Home  About Us  Products  Applications  Contact Us

Formex™ GK Product Data
Flame Retardant Polypropylene Sheet

Product Features

  • UL 94V-0 Flame Class Rating

  • Non-hygroscopic (moisture absorption <0.1%)

  • Excellent dielectric strength

  • Superior score and fold ability

  • Economical

See this page in PDF format

See UL Yellow Card for this product

See other products.
 

See chart for Formex GK-30, Formex GK-40, and Formex GK-62.
 

  Test Method Formex GK-5BK Formex GK-10 Formex GK-17
    Order Samples Order Samples Order Samples
Color   Black Natural & Black Natural & Black
Thickness - inch   .005 ± .001 .010 + .003 / -.0015 .017 + .003 / -.001
Thickness - millimeter   .127 ± .025 .25 + .08 / -.04 .43 + .08 / -.03
MECHANICAL PROPERTIES Test Method Formex GK-5BK Formex GK-10 Formex GK-17
    Order Samples Order Samples Order Samples
Tensile Yield - psi ASTM D-882      
     Machine Direction   4400 4400 4400
     Transverse Direction   3200 3200 3200
PHYSICAL PROPERTIES Test Method Formex GK-5BK Formex GK-10 Formex GK-17
    Order Samples Order Samples Order Samples
Density - gm/cc ASTM D-792 1.035 1.035 1.035
Flammability UL 94 VTM-0 VTM-0 V-0
Oxygen Index ASTM D-2863 29 29 29
Water Absorption - % change in weight ASTM D-570 0.06% 0.06% 0.06%
Heat Deflection Temperature at 66 psi ASTM D-648 121°C/250°F 121°C/250°F 121°C/250°F
Relative Thermal Index UL 746B      
     Electrical   115°C/239°F 115°C/239°F 115°C/239°F
     Mechanical Without Impact   115°C/239°F 115°C/239°F 115°C/239°F
Surface Energy - dynes/cm (as produced) ASTM D-2578 ≥50 outside only** ≥50 ≥50
ELECTRICAL PROPERTIES Test Method Formex GK-5BK Formex GK-10 Formex GK-17
    Order Samples Order Samples Order Samples
Dielectric Breakdown - volts ASTM D-149 13,125 22,000 24,820
Dielectric Strength - volts/mil ASTM D-149 2625 2200 1460
Volume Resistivity - ohm-cm ASTM D-257 3.97x1015 3.97x1015 3.97x1015
Dielectric Constant ASTM D-150 2.30 2.30 2.30
Dissipation Factor ASTM D-150 0.0019 0.0019 0.0019
High Current Arc Ignition - arcs to ignite UL 746A 200 200 162
High Voltage Arc Tracking - in/min UL 746A 0.0 0.0 0.0
Hot Wire Ignition - seconds UL 746A 9 7 9
Comparative Tracking Index - volts ASTM D-3638 600 600 600
PACKAGING INFORMATION Test Method Formex GK-5BK Formex GK-10 Formex GK-17
    Order Samples Order Samples Order Samples
Standard Configuration   Roll Roll Roll & Sheet
Core ID - inches   6 6 6
Roll OD - inches (approximate)   18 18 18
Roll Width - inches   24 24 24 & 25
Roll Weight - lbs (approximate)   205 225 200
Length/Roll - feet   4000 2000 1000
Area/Roll - square feet   8000 4000 2000 & 2083
Sheet Sizes - inches   - - 24 x 48
    See chart for Formex GK-30, Formex GK-40, and Formex GK-62.

**Treated one side only

Notice: The above information is believed to be accurate and reliable. ITW assumes no responsibility for end use applications and no performance warranty is expressed or implied.

MIL Handbook 454 - Fungus-inert-Group I
FMVSS 302-75: SE
US. Govt. CAGE Code No.: 3VHK9

For a complete listing of Formex products, contact your Formex/Statex sales representative.

 
Home | Contact Us | Technical Lit | Request Samples